Description of this case:

Achromatic Telescopic Squeeze (ATS) at 7 TeV with TCLD collimators.
In this case, a thin marker for a TCLD collimator (similar to TCL) has been to the sequence in both cells 8R7 and 10R7, without modifying the optics.
For IP1 and IP5: Beta*=0.15m; for IP2 and IP8: Beta*=10m.

Primaries and secondaries    Tertiaries
NSIG_TCP3 12.
NSIG_TCSG3 15.6
NSIG_TCSM3 999.
NSIG_TCLA3 17.6
NSIG_TCP7 6.
NSIG_TCSG7 7.
NSIG_TCSM7 999.
NSIG_TCLA7 10.
NSIG_TCLP 12.
NSIG_TCLI 999.
NSIG_TCDQ 8.
NSIG_TCSTCDQ7.5
NSIG_TDI 999.
     
NSIG_TCTH1 8.3
NSIG_TCTH2 30.
NSIG_TCTH5 8.3
NSIG_TCTH8 30.
NSIG_TCTV1 8.3
NSIG_TCTV2 30.
NSIG_TCTV5 8.3
NSIG_TCTV8 30.
NSIG_TCXRP 999.
NSIG_TCRYO 999.


Inputs B1, ATS Beta*=15cm, TCLDs

Halo setting = 6. sigma (setting of primary collimator).
The two TCLDs are set at 10 sigma. Send us an email, and we'll send you the following input files:

fort.2 CollDB file
fort.3 CollPositions file


B1 Horizontal halo results, ATS Beta8=15cm, TCLDs.

Loss map LHC
Loss map IR7

ColUSM website, CERN. Last update: October 2013